Door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
Maximum size of ada door handle obstruction.
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches 455 mm of the latch side of a doorway projects more than 8 inches 205 mm beyond the face of the door measured perpendicular to the face of the door or gate.
The door shall be self closing.
4 2 6 side reach if the clear floor space allows parallel approach by a person in a wheelchair the maximum high side reach allowed shall be 54 in 1370 mm and the low side reach shall be no less than 9 in 230 mm above the floor.
In general the requirements are a minimum of 32 in width and a maximum of 48 and the door must open to 90 degrees.
Minimum of 18 inches minimum between the latch side and any obstruction a wall columns objects etc for a forward approach to the door.
The width of an exit route must be sufficient to accommodate the maximum permitted occupant load of each floor served by the exit route.
The size of the building.
Operable parts shall be operable with one hand and shall not require tight grasping pinching or twisting of the wrist.
Handles pulls panic bars.
Door pressure gauges and other products are available to measure the opening force.
Door openings shall provide a clear width of 32 inches 815 mm minimum.
Fire resistance rated glazing tested to astm e 119 or ul 263 and nfpa 252 ul 10b or ul 10c shall be permitted in fire door assemblies located in fire walls and in fire barriers in accordance with table 716 5 to the maximum size tested and in accordance with their listings.
Such devices like other door and gate hardware must operate with a maximum 5 lbf force 404 2 7 but their operating force is not included in the measure of door or gate opening force.
Door opening space from the face of the door up to stop of the door frame must be between 32 inches minimum to a 48 inches maximum.
Section 404 of the ada states.
Toilet compartment doors including door hardware shall comply with 404 except that if the approach is to the latch side of the compartment door clearance between the door side of the compartment and any obstruction shall be 42 inches 1065 mm minimum.
Size min 3 0 wide 32 clear when 90 open and 6 8 in height.
Effort to operate doors 8 5 pounds at exterior doors and 5 pounds at interior doors door hardware height 30 44 above floor.
Each fire door including its frame and hardware must be listed or approved by a nationally recognized testing laboratory.